Switch-disconnector

Switch-disconnector-fuse combinations

Disconnector

Up to 36 kV

 

Catalogue

ISP and ISPF Instructions Manual

SE Instructions Manual

 

Switch-disconnector ISP, switch-disconnector-fuse combinations ISPF and disconnector SE are an homogenous family of  MV indoor equipments for use in open substations.

 

The integrated concept uses only one type of operating mechanism, which makes for easy installation and interchangeability.

 

Switch and switch-fuse  combinations ISP e ISPF series


 

 

GENERAL CHARACTERISTICS

 

IEC 256-1 (1986) states:

  • General purpose switches capable of making 20 operating cycles (CO) at current rate.

  • "Increased operating frequency" switches capable of making 100 operating cycles (CO) at rated current.

EFACEC has designs for both categories:

  • ISP and ISPF for general purpose

  • ISPB and ISPBF of "increased operating frequency"

Technical characteristics are shown in technical data table.

 

Switch disconnector system are ISP/ISPF is based on a modular system, that permits switch-fuse combinations (ISPF/ISPBF) by the simple addition of fuse bases and striker pin fuse links in accordance with IEC 420 standards.

 

Switch-fuse combinations offer a more economical option to circuit breakers on system up to 36 kV by promoting three-pole tripping with striker pin fuses.

 

The tripping and closing speeds of main and arcing contact blades are independent of the operator.

Interrupting current operating principle:

  • On opening the arcing contact blade is retained in the quenching chamber by a latch, it only opens after the main blades attain the correct isolating distance then moves a high speed, breaking the current.

  • During this process the arc is drawn within the quenching chamber, cooled, suppressed and blown by the large volume of gas released, resulting in arc extinction.

  • The extinction takes place before the arcing contact leaves the quenching chamber, assuring complete safety.

Our switches offer:

  • High breaking capacity

  • Full operating safety

  • Visible isolating distance

  • Readily accessible contacts

  • Minimum maintenance

  • Easy and sturdy construction

  • Minimum space requirements

  • Approved characteristics (see Type Tests table)

 

 

TECHNICAL DATA (1)

 

TYPE

RATED VOLTAGE

(kV)

RATED CURRENT

(A)

RATED SHORT TIME WITHSTAND CURRENT

(3 S) (kA)

RATED SHORT CIRCUIT MAKING CURRENT

(kA ampl.)

RATED WITHSTAND VOLTAGE TO EARTH AND BETWEEN POLES ACROSS ISOLATING DISTANCE

CABLE-CHARNGING BREAKING CAPACITY

(A)

CATEGORY ACCORDING TO

IEC 265-1

50 Hz-1 min.

(kV ef.)

Lightning inpulse

(kV max.)

ISP 12 / ISPF 12 12 400 16 40 28 / 32 75 / 85 25 GENERAL PURPOSE (2)
ISPB 12 / ISPBF 12 200 INCREASED OPERATING FREQUENCY (3)
400
ISP 17,5 / ISPF 17,5 17,5 400 16 40 38 / 45 95 / 110 25 GENERAL PURPOSE (2)
ISPB 17,5 / ISPBF 17,5 200 INCREASED OPERATING FREQUENCY (3)
400
ISP 24 / ISPF 24 24 400 16 40 50 / 60 125 / 145 25 GENERAL PURPOSE (2)
ISPB 24 / ISPBF 24 200 INCREASED OPERATING FREQUENCY (3)
400
ISP 36 / ISPF 36 36 200 12,5 31,5 70 / 80 170 / 195 10 GENERAL PURPOSE (2)
ISPb 36 / ISPbF 36 INCREASED OPERATING FREQUENCY (3)

(1) Complies with IEC 265-1 and CEI 420. Other ratings upon request.

(2) 20 closing/opening operating cycles at rated current.

(3) 100 closing/opening operating cycles at rated current.

 

TYPE TESTS

 

The above mentioned characteristics where tested at KEMA Laboratories - Holland, CESI Italy and EFACEC, on each type manufactured by EFACEC.

 

TYPE TEST

LABORATORY

REPORT

Making and breaking

CESI

912

Short circuit making capacity

KEMA

298-84

Short time withstand current (main switch)

KEMA

298-84

Peak withstand current (main switch)

KEMA

298-84

Short time withstand current (earth switch)

KEMA

297-84

Peak withstand current (earth switch)

KEMA

297-84

TYPE TEST

LABORATORY

REPORT

On laod transformer breaking

EFACEC

KEMA

84.119/TI

298-84

Cable charging making and breaking

KEMA

298-84

Mechanical endurance

EFACEC

84-519

Temperature rise

EFACEC

84-515

84-527

1 min. power frequency withstand test 50 Hz

EFACEC

84-518

84-528

Lightning impulse withstand tests -  1,2 / 50 µs

EFACEC

84-305

84-323

CESI  - Italian Electronics Laboratory, Milano

KEMA - Holand Electronic Laboratory, Arnhem.

 

DIMENSIONAL DATA AND WEIGHT

 

SWITCH-DISCONNECTOR

(ISP OU ISPB)

 

 

 

 

SWITCH -DISCONNECTOR-FUSE COMBINATION

(ISPF OU ISPBF)

 

TYPE DIMENSIONS (mm) WEIGHT (kg)
a b c d e f g h k l m n o p q r s t u v

S/F.T.

C/F.T.

ISP 12 / ISPB 12 452 261 165 488 465 516 760 - 287 290 218 320 257 450 370 40 47 344 60 - 25 37
ISPF 12 / ISPBF 12 420 453 580 711 295 42 54
ISP 17,5 / ISPB 17,5 497 306 210 598 540 626 890 - 332 335 218 320 287 480 400 40 47 374 60 - 32 44
ISPF 17,5 / ISPBF 17,5 615 603 760 891

375*

445·

48 60
ISP 24 / ISPB 24 532 341 300 778 640 806 1070 - 367 370 218 320 358 551 400 40 47 445 60 - 41 54
ISPF 24 / ISPBF 24 650 603 831 962 445 57 71
ISP 36 / ISPB 36 692 431 400 978 810 1008 1270 275 457 460 218 320 437 630 550 40 47 524 60 - 40 55
ISPF 36 / ISPBF 36 835 698 1006 1136 540 60 75

* For equipment with 17,5 kV fuses

· For equipment with 24 kV fuses

 

EQUIPMENTS (PROVIDED ON REQUEST)

 

HRC Fuses: HRC fuses may be combined in the switches to form combinations ISPF / ISPBF with dimensions in accordance with DIN 43625.

 

NOTE: The 24 kV switch-fuse combination will accept 17.5 kV fuses by simply moving the lower connectors (see note in Dimensional Data and Weight table).

 

Earthing switches: Earthing switches can also be provided with a high making current capability, with it's own operating control which is independent of the main switch and can be assembled in the same or opposite side to the main switch handle.

Earthing blades are interlocked to prevent closure of the main switch when in the earthing position. The earth switches can be provided on either side or both sides on the main contacts.

 

Auxiliary contacts: A set of 4 auxiliary contacts (1NO + 1NC + 1NOL + 1NCL) are standard for all aparatus. Upon request we can provide contacts up to the maximum of 12.

 

Shunt trip coil: Opening by remote control can be achieved by provision of a shunt trip coil. Rated voltage: 200 Vac - 50 HZ (other voltages upon request). To avoid continuous energizing of the coil it is possible to insert in series one auxiliary conact,

 

Shaft extensions and supplementary cradle: If the switch-disconnector shaft is not long enough we can provide shaft extensions with supplementary cradle (L=500 or L=1000 mm).

 

 

 

Seccionadores séries SE


 

 

GENERAL CHARACTERISTICS

 

SE series disconnectors, made by EFACEC according to IEC 129 and 694 standards, are robust and reliable and are primarily used sectionalizing and isolating purpouses in MV (up to 36 kV) networks allowing a visual observation of the "open" and "closed" position.

 

Description and operating principle:

  • Permits direct wall mounting or frame mounting.

  • Epoxy resin support insulators and insulating links.

  • Silver plated moving blades.

The three poles are operated simultaneously through a square section operating shaft which permits shaft extension can be fitted on right or left side at different lengths making local adaptation to site installation conditions possible.

 

TECHNICAL DATA (1)

 

TYPE

RATED VOLTAGE

(kV)

RATED CURRENT

(A)

RATED SHORT TIME WITHSTAND CURRENT (3 seg.)

(kA)

RATED WITHSTAND VOLTAGE TO EARTH AND BETWEEN POLES ACROSS ISOLATING DISTANCE

50 Hz - 1 min.

(kV)

LIGHTNING IMPULSE

(kV máx.)

SE 17,5 17,5 630 12,5 38 / 45 95 / 110
SE 24 24 400 12,5 50 / 60 125 / 145
SE 36 36 400 8 70 / 80 170 / 195

(1) Performance data in accordance with IEC 129 standards. Other characteristics upon request.

 

 

DIMENSIONAL DATA AND WEIGHT

DISCONNECTOR

(SE)

 

 

TYPE DIMENSIONS (mm) WEIGHT (kg)
A B C D E F G H J L M N W/o earth switch W/ earth switch
(1) (2) (3) (4)
SE 17,5 634 430 598 400 435 480 640 1500 210 245 517 406 30 12,2 12 16 20
SE 24 814 470 778 400 535 570 730 1590 300 280 650 446 30 12,2 12 25 30
SE 36 1014 710 978 550 765 765 1000 1500 400 370 820 686 30 12,2 12 35 42

(1) Minimum electrical value to assure insulation level: 375 to 12 kV.

(2) Maximum, with standard shaft extension and without supplementary bearing.

(3) Maximum, with standard shaft extension and with supplementary bearing.

(4) Maximum, with special shaft extension and supplementary bearing.

 

EQUIPMENT (PROVIDED UPON REQUEST)

 

Earth switch: the earth switch is operated by it's own mechanism (see Operating Mechaism). Control is independent of the main switch and can be assembled on the same or opposite side of the main operating handle. A mechanical locking device prevents closure of the earth switch while the main switch is in the closed position.

 

Auxiliary contacts: A set of 2 or 4 auxiliary contacts (1NO + 1NC + 1NOL + 1NCL) are standard for all apparatus.

 

Special shaft extensions: These are required for special applications between disconnector and the lever (see dimension "E" of Dimensional Data and Weight table).

 

supplementary cradle: These are required to support standard or special shaft extensions (see Dimensional Data and Weight table).

 

 

OPERATING MECHANISM

 

Both ISP switches and ISPF combinations and SE disconnectors are provided with the same type of control mechanism. Upon request disconnectors can be fitted with direct control.

 

The "O" type mechanism is operated by a handle via a tubular connecting rod. This connecting rod is a tube 3/4'' dia. that only will be provided upon request. The length of this tube must not exceed 3 m (see ACCESSORIES).

 

The drawing below represents the most common installation arrangement for this control mechanism, for the complete of ISP, ISPF and SE without accessories.

 

For special arrangements that will need angle links, locking devices, etc., please contact our Commercial Service.

 

ARRANGEMENTS

 

LATERAL CONTROL

FRONT CONTROL

DIMENSIONS ("O" TYPE MECHANISM)

Weight: 4.5 kg

ACCESSORIES (PROVIDED UPON REQUEST)

  • Intermediate bearing: Whenever the distance between operating mechanism and equipment exceeds 3 m, it is required that one or more bearings be positioned along its length. The operating tube is a 3/4'' dia. and will be provided upon request.

  • Angle link: This accessory makes possible a 90º deviation of the connecting rod which makes the connection between the "O" type manual operating mechanism and the equipment.

  • Interlocks: The "O" type mechanism can be fitted with locks. These locks retain the key during closing and sets it free in the open and locked position. The key may be used to operate other equipment or devices (doors for example).

INFORMATION REQUIRED WITH ORDER

  • Type of equipment, rated voltage and current.

  • Accessories and fittings.

 

 